Coal & Coke Testing Equipment
Thermostatic Drying Oven 202 Series for Laboratory Baking and Moisture Determination
Item Number : KT-TE15
Price varies based on specs and customizations
- Temperature Control Range
- RT+20 to 250°C
- Temperature Fluctuation
- ±1°C
- Temperature Uniformity
- ±2.5%
Shipping:
Contact us to get shipping details Enjoy On-time Dispatch Guarantee.
Why Choose Us
Easy ordering process, quality products, and dedicated support for your business success.
Product Overview

This thermostatic drying oven provides dependable thermal processing for routine laboratory drying, sample baking, and precision moisture determination across diverse analytical workflows. Designed to deliver consistent thermal conditioning from ambient +20°C up to 250°C, the equipment combines reliable resistance heating with precision PID micro-processing to maintain tight thermal equilibrium. Its balanced air distribution ensures that sensitive analytical materials undergo uniform moisture loss without localized scorching or thermal degradation.
Built for demanding industrial and scientific environments, the system serves chemical analysis facilities, industrial and mining enterprises, coal inspection stations, materials research centers, academic institutions, and medical testing laboratories. It is especially suited for routine volatile loss measurements, gravimetric coal moisture assays, component pre-heating, and glassware decontamination. The unit provides laboratory technicians with straightforward operational controls and continuous sample visibility through a dedicated observation pane.
Constructed with a heavy-gauge cold-rolled exterior and resilient interior liner configurations, this equipment guarantees dependable performance under rigorous testing regimens. High-grade insulation and robust temperature-resistant boundary seals minimize perimeter thermal leakage, reducing energy consumption and maintaining a cool exterior casing. Every assembly is manufactured to withstand non-stop daily cycles, ensuring repeatable analytical data and long service life.
Detail & Parts

Key Features
- Precision PID Temperature Control: An integrated digital PID microprocessor utilizes time-proportional regulation and platinum resistance temperature detection to maintain thermal fluctuation within ±1°C, guaranteeing repeatable thermodynamic conditions across the entire heating spectrum.
- Dual Liner Material Configurations: Available with either a treated anti-corrosion cold-rolled steel chamber (Type A) for standard drying operations or a corrosion-resistant stainless steel chamber (Type B) designed for aggressive volatile testing and high-humidity environments.
- Double-Layer Tempered Glass Window: The central observation pane features twin layers of industrial tempered glass, allowing technicians to inspect sample conditions in real time without opening the door and destabilizing internal chamber temperatures.
- High-Temperature Hermetic Door Seal: An embedded, resilient high-temperature synthetic gasket borders the door perimeter, delivering a tight compression seal that eliminates thermal bridging, protects laboratory personnel, and maintains uniform internal heat.
- Integrated Moisture Exhaust Port: A top-mounted adjustable vent valve actively exhausts vaporized moisture and volatile byproducts generated during sample desiccation, expediting drying cycles and preventing condensation re-deposition.
- Rugged Multi-Tier Shelf Design: Reinforced internal shelves support up to 15 kg per layer, accommodating heavy mineral samples, metal tooling, or dense glassware arrays while preserving unobstructed vertical thermal circulation.
- Electrostatic Powder-Coated Exterior: The outer chassis is fabricated from premium cold-rolled steel sheets treated with an advanced electrostatic spray coating that resists scratch damage, chemical splatter, and ambient laboratory corrosion.
- Clear Digital LED Display: The intuitive control fascia clearly displays real-time and setpoint temperatures, enabling rapid verification from across the laboratory and streamlining routine operational monitoring.
Applications
| Application | Description | Key Benefit |
|---|---|---|
| Coal Moisture Determination | Desiccating pulverized coal samples under stable heating to quantify inherent and total moisture percentages according to standard ASTM/ISO testing methods. | Consistent ±2.5% temperature uniformity eliminates regional hot zones, preventing volatile loss and sample carbonization during gravimetric assays. |
| Mining & Mineral Ore Drying | Removing moisture from geological core samples, mineral slimes, and crushed rock specimens prior to chemical digestion, sieving, or XRF/XRD analysis. | Heavy-duty internal shelving holds up to 15 kg per layer, easily bearing high-density mineral specimens without shelf deflection. |
| Glassware & Tool Decontamination | Sterilizing, evaporating wash liquids, and thoroughly baking laboratory glassware, volumetric pipettes, metal dies, and surgical apparatus. | Top exhaust damper efficiently vents high volumes of vaporized rinse water, accelerating cycle turnaround times. |
| Industrial Component Baking | Curing, conditioning, and pre-heating mechanical fasteners, electrical assemblies, and polymer coatings within manufacturing QA/QC processes. | Dual-layer tempered glass window allows visual inspection of adhesive setting and thermal deformation without opening the chamber door. |
| Pharmaceutical & Chemical R&D | Moisture testing of dry chemical powders, excipients, and raw compounds requiring non-destructive heat processing up to 250°C. | Type B stainless steel interior resists chemical degradation from mildly corrosive volatile emissions during long-term desiccation. |
| Academic & Environmental Testing | Thermal preparation of environmental soil samples, wastewater sludge cakes, and educational laboratory specimens. | Streamlined digital PID control interface allows rapid parameter setup by multiple rotating operators with minimal training requirements. |
Technical Specifications
| Technical Parameter | KT-TE15-00 | KT-TE15-0 | KT-TE15-1 | KT-TE15-2 | KT-TE15-3 |
|---|---|---|---|---|---|
| Model Variant Identification | KT-TE15-00A / KT-TE15-00B | KT-TE15-0A / KT-TE15-0B | KT-TE15-1A / KT-TE15-1B | KT-TE15-2A / KT-TE15-2B | KT-TE15-3A / KT-TE15-3B |
| Operating Voltage | 220V, 50Hz | 220V, 50Hz | 220V, 50Hz | 220V, 50Hz | 220V, 50Hz |
| Temperature Control Range | Ambient +20°C to 250°C | Ambient +20°C to 250°C | Ambient +20°C to 250°C | Ambient +20°C to 250°C | Ambient +20°C to 250°C |
| Temperature Fluctuation | ±1°C | ±1°C | ±1°C | ±1°C | ±1°C |
| Temperature Uniformity | ±2.5% | ±2.5% | ±2.5% | ±2.5% | ±2.5% |
| Rated Heating Power | 0.6 kW | 1.2 kW | 1.6 kW | 2.0 kW | 4.0 kW |
| Internal Chamber Dimensions (W × D × H) | 280 × 280 × 280 mm | 350 × 350 × 350 mm | 450 × 450 × 350 mm | 550 × 550 × 450 mm | 750 × 600 × 500 mm |
| Chamber Construction (Type A) | Anti-corrosion cold-rolled steel | Anti-corrosion cold-rolled steel | Anti-corrosion cold-rolled steel | Anti-corrosion cold-rolled steel | Anti-corrosion cold-rolled steel |
| Chamber Construction (Type B) | High-grade stainless steel | High-grade stainless steel | High-grade stainless steel | High-grade stainless steel | High-grade stainless steel |
| Exterior Cabinet Material | Cold-rolled steel with electrostatic coating | Cold-rolled steel with electrostatic coating | Cold-rolled steel with electrostatic coating | Cold-rolled steel with electrostatic coating | Cold-rolled steel with electrostatic coating |
| Observation Window | Dual-layer tempered glass pane | Dual-layer tempered glass pane | Dual-layer tempered glass pane | Dual-layer tempered glass pane | Dual-layer tempered glass pane |
| Door Perimeter Sealing | High-temperature synthetic rubber strip | High-temperature synthetic rubber strip | High-temperature synthetic rubber strip | High-temperature synthetic rubber strip | High-temperature synthetic rubber strip |
| Control Architecture | PID digital controller with time-proportional regulation | PID digital controller with time-proportional regulation | PID digital controller with time-proportional regulation | PID digital controller with time-proportional regulation | PID digital controller with time-proportional regulation |
| Temperature Sensor Type | Platinum resistance sensor | Platinum resistance sensor | Platinum resistance sensor | Platinum resistance sensor | Platinum resistance sensor |
| Moisture Exhaust System | Top-mounted adjustable manual damper | Top-mounted adjustable manual damper | Top-mounted adjustable manual damper | Top-mounted adjustable manual damper | Top-mounted adjustable manual damper |
| Shelf Load Bearing Capacity | 15 kg / shelf | 15 kg / shelf | 15 kg / shelf | 15 kg / shelf | 15 kg / shelf |
Why Choose This Product
- Reliable Long-Term Thermal Uniformity: Incorporates an advanced platinum resistance sensor paired with digital PID logic, ensuring that internal temperature fluctuations remain strictly within ±1°C and spatial uniformity conforms to ±2.5% for highly reproducible gravimetric test results.
- Application-Specific Chamber Tailoring: Available in five distinct chamber volumes ranging from compact benchtop footprints to high-throughput 225-liter capacities, complemented by a choice between economical anti-corrosion cold-rolled steel (Type A) and chemical-resistant stainless steel (Type B) interiors.
- Enhanced Structural and Thermal Integrity: Built with heavy cold-rolled exterior steel, dual-layer insulated tempered viewing glass, and durable perimeter door sealing, reducing shell temperature, minimizing thermal waste, and maintaining a safer operator environment.
- Operational Simplicity and Moisture Management: The manual top exhaust port provides smooth, on-demand evacuation of saturated air during high-moisture drying cycles, preventing condensation buildup on internal walls and speeding up total analytical turnaround.
Contact KINTEK today to discuss your specific thermal processing parameters, request detailed technical schematics, or receive a customized quotation for your laboratory.
Trusted by Industry Leaders
Product Datasheet
Thermostatic Drying Oven 202 Series for Laboratory Baking and Moisture Determination
REQUEST A QUOTE
Our professional team will reply to you within one business day. Please feel free to contact us!
Related Products
Laboratory Scientific Electric Heating Blast Drying Oven
The desktop fast autoclave sterilizer is a compact and reliable device used for rapid sterilization of medical, pharmaceutical, and research items.
23L Laboratory Vacuum Drying Oven
Kintek Intelligent Vacuum Drying Oven for labs: precise, stable, low-temp drying. Ideal for heat-sensitive materials. Get a quote now!
56L Vertical Laboratory Vacuum Drying Oven
Discover the 56L Laboratory Vacuum Drying Oven for precise, low-temperature sample dehydration. Ideal for biopharma & materials science.
High Temperature Muffle Oven Furnace for Laboratory Debinding and Pre Sintering
KT-MD High temperature debinding and pre-sintering furnace for ceramic materials with various molding processes. Ideal for electronic components such as MLCC and NFC.
Laboratory Muffle Oven Furnace Bottom Lifting Muffle Furnace
Efficiently produce batches with excellent temperature uniformity using our Bottom Lifting Furnace. Features two electric lifting stages and advanced temperature control up to 1600℃.
Graphite Vacuum Furnace High Thermal Conductivity Film Graphitization Furnace
The high thermal conductivity film graphitization furnace has uniform temperature, low energy consumption and can operate continuously.
Multi-zone Laboratory Tube Furnace
Experience precise, efficient thermal testing with our Multi Zone Tube Furnace. Independent heating zones and temperature sensors allow for controlled high-temperature gradient heating fields. Order now for advanced thermal analysis!
10L Heating Chilling Circulator Cooling Water Bath Circulator for High and Low Temperature Constant Temperature Reaction
Experience efficient lab performance with KinTek KCBH 10L Heating Chilling Circulator. Its all-in-one design offers reliable heating, chilling, and circulating functions for industrial and lab use.