Knowledge How do the liquid junction bridge and glass filter function in corrosive media? Protect Your Electrochemical Sensors
Author avatar

Tech Team · Kintek Solution

Updated 1 day ago

How do the liquid junction bridge and glass filter function in corrosive media? Protect Your Electrochemical Sensors


The liquid junction bridge and glass filter function as a protective interface system. They establish a necessary ionic conduction path between the harsh test electrolyte and the sensitive reference electrode without allowing them to mix. By utilizing a glass tube filled with high-concentration nitric acid and a glass filter, this design maintains electrical connectivity while physically isolating the reference sensor from damaging environments.

This configuration solves the critical problem of sensor degradation in extreme media. It effectively decouples the reference electrode from radioactive or corrosive contaminants, such as plutonium nitrate, ensuring long-term measurement stability and extended component lifespan.

The Mechanics of Isolation and Conduction

The primary challenge in analyzing corrosive or radioactive media is that standard reference electrodes (like silver/silver chloride) are easily fouled by the test solution. The bridge and filter system solves this through a dual-mechanism approach.

The Role of the Liquid Junction Bridge

The bridge itself is a glass tube that acts as an intermediate chamber. It is filled with a specific electrolyte—in this case, high-concentration nitric acid.

This acid serves as the conductive medium, bridging the gap between the test solution and the reference electrode. It allows the transfer of charge necessary for electrochemical measurements without exposing the electrode directly to the sample.

Function of the Glass Filter

The glass filter is the physical gatekeeper of the system. It is positioned at the interface between the bridge electrolyte and the radioactive test solution.

Its porous structure permits the movement of ions to sustain the electrical circuit. However, it significantly restricts the bulk flow of liquid, preventing the radioactive media from migrating up the tube and contaminating the bridge solution.

Protecting the Reference Electrode

The ultimate goal of this design is the preservation of the reference electrode's integrity.

Preventing Contamination

In environments containing plutonium nitrate or similarly hazardous materials, direct contact would ruin a standard electrode. The silver/silver chloride element must remain pristine to provide a stable reference potential.

By placing the electrode behind the "shield" of the nitric acid bridge and glass filter, the system ensures that plutonium ions never reach the sensor surface.

Ensuring Measurement Stability

Contamination leads to drift in potential readings, rendering data useless over time.

By maintaining a clean environment for the reference electrode, this isolation method ensures consistent, reliable potential measurements. This allows for long-term monitoring of the radioactive solution without the need for frequent, dangerous electrode replacements.

Understanding the Trade-offs

While this system provides essential protection, it introduces complexity that must be managed.

Liquid Junction Potentials

Introducing a bridge creates a "liquid junction" where the nitric acid meets the test solution. This interface generates a small, additional voltage (junction potential) that can influence the total measurement.

Maintenance and Clogging

The glass filter is a physical restriction. In solutions with high particulate matter or precipitates, the pores of the filter can eventually clog, increasing resistance and potentially disrupting the measurement.

Making the Right Choice for Your Design

When designing electrochemical cells for hazardous media, you must balance protection with signal fidelity.

  • If your primary focus is Component Longevity: Prioritize a robust bridge with a fine-porosity glass filter to maximize the physical isolation of the reference electrode from radioactive elements.
  • If your primary focus is Measurement Stability: Ensure the high-concentration nitric acid in the bridge is compatible with your test solution to minimize erratic liquid junction potentials.

This design is the industry standard for safe, accurate electrochemical analysis in radioactive and highly corrosive environments.

Summary Table:

Component Primary Function Key Material/Mechanism Benefit to System
Liquid Junction Bridge Ionic Conduction Path High-concentration Nitric Acid Prevents direct contact between sensor and hazardous media
Glass Filter Physical Isolation Porous Barrier Restricts bulk fluid flow while allowing ion migration
Reference Electrode Potential Measurement Ag/AgCl (Isolated) Maintains long-term stability and prevents sensor fouling
Test Electrolyte Media Analysis Corrosive/Radioactive (e.g., Pu Nitrate) Allows for safe analysis of extreme chemical environments

Maximize Your Lab's Analytical Precision with KINTEK

Handling corrosive and radioactive media requires specialized equipment that doesn't compromise on accuracy or safety. KINTEK specializes in advanced laboratory solutions, offering a comprehensive range of electrolytic cells and electrodes specifically designed for challenging environments.

Whether you are conducting battery research, high-temperature furnace operations, or complex chemical processing, our portfolio—including high-pressure reactors, autoclaves, and precision ceramic consumables—is engineered to extend the lifespan of your components and ensure measurement stability.

Don't let sensor degradation halt your research. Contact our technical experts today to find the perfect electrochemical setup for your application!

Related Products

People Also Ask

Related Products

Electrolytic Electrochemical Cell for Coating Evaluation

Electrolytic Electrochemical Cell for Coating Evaluation

Looking for corrosion-resistant coating evaluation electrolytic cells for electrochemical experiments? Our cells boast complete specifications, good sealing, high-quality materials, safety, and durability. Plus, they're easily customizable to meet your needs.

Super Sealed Electrolytic Electrochemical Cell

Super Sealed Electrolytic Electrochemical Cell

Super-sealed electrolytic cell offers enhanced sealing capabilities, making it ideal for experiments that require high airtightness.

Electrolytic Electrochemical Cell with Five-Port

Electrolytic Electrochemical Cell with Five-Port

Streamline your laboratory consumables with Kintek's Electrolytic Cell with five-port design. Choose from sealed and non-sealed options with customizable electrodes. Order now.

Electrolytic Electrochemical Cell Gas Diffusion Liquid Flow Reaction Cell

Electrolytic Electrochemical Cell Gas Diffusion Liquid Flow Reaction Cell

Looking for a high-quality gas diffusion electrolysis cell? Our liquid flow reaction cell boasts exceptional corrosion resistance and complete specifications, with customizable options available to suit your needs. Contact us today!

Double-Layer Water Bath Electrolytic Electrochemical Cell

Double-Layer Water Bath Electrolytic Electrochemical Cell

Discover the temperature-controllable electrolytic cell with a double-layer water bath, corrosion resistance, and customization options. Complete specifications included.

Quartz Electrolytic Electrochemical Cell for Electrochemical Experiments

Quartz Electrolytic Electrochemical Cell for Electrochemical Experiments

Looking for a reliable quartz electrochemical cell? Our product boasts excellent corrosion resistance and complete specifications. With high-quality materials and good sealing, it's both safe and durable. Customize to meet your needs.

PTFE Electrolytic Cell Electrochemical Cell Corrosion-Resistant Sealed and Non-Sealed

PTFE Electrolytic Cell Electrochemical Cell Corrosion-Resistant Sealed and Non-Sealed

Choose our PTFE Electrolytic Cell for reliable, corrosion-resistant performance. Customize specifications with optional sealing. Explore now.

Flat Corrosion Electrolytic Electrochemical Cell

Flat Corrosion Electrolytic Electrochemical Cell

Discover our flat corrosion electrolytic cell for electrochemical experiments. With exceptional corrosion resistance and complete specifications, our cell guarantees optimal performance. Our high-quality materials and good sealing ensure a safe and durable product, and customization options are available.

Customizable PEM Electrolysis Cells for Diverse Research Applications

Customizable PEM Electrolysis Cells for Diverse Research Applications

Custom PEM test cell for electrochemical research. Durable, versatile, for fuel cells & CO2 reduction. Fully customizable. Get a quote!

H-Type Double-Layer Optical Electrolytic Electrochemical Cell with Water Bath

H-Type Double-Layer Optical Electrolytic Electrochemical Cell with Water Bath

Double-layer H-type optical water bath electrolytic cells, with excellent corrosion resistance and a wide range of specifications available. Customization options are also available.

Customizable Swagelok Type Test Cells for Advanced Battery Research Electrochemical Analysis

Customizable Swagelok Type Test Cells for Advanced Battery Research Electrochemical Analysis

The KINTEK Swagelok-type test cell is a modular, T-shaped device constructed from high-quality, chemically inert materials.

Side Window Optical Electrolytic Electrochemical Cell

Side Window Optical Electrolytic Electrochemical Cell

Experience reliable and efficient electrochemical experiments with a side window optical electrolytic cell. Boasting corrosion resistance and complete specifications, this cell is customizable and built to last.

FS Electrochemical Hydrogen Fuel Cells for Diverse Applications

FS Electrochemical Hydrogen Fuel Cells for Diverse Applications

KINTEK's FS Electrochemical Cell: Modular PEM fuel cell stack for R&D and training. Acid-resistant, scalable, and customizable for reliable performance.

H Type Electrolytic Cell Triple Electrochemical Cell

H Type Electrolytic Cell Triple Electrochemical Cell

Experience versatile electrochemical performance with our H-type Electrolytic Cell. Choose from membrane or non-membrane sealing, 2-3 hybrid configurations. Learn more now.

Customizable CO2 Reduction Flow Cell for NRR ORR and CO2RR Research

Customizable CO2 Reduction Flow Cell for NRR ORR and CO2RR Research

The cell is meticulously crafted from high-quality materials to ensure chemical stability and experimental accuracy.

Thin-Layer Spectral Electrolysis Electrochemical Cell

Thin-Layer Spectral Electrolysis Electrochemical Cell

Discover the benefits of our thin-layer spectral electrolysis cell. Corrosion-resistant, complete specifications, and customizable for your needs.

Multifunctional Electrolytic Electrochemical Cell Water Bath Single Layer Double Layer

Multifunctional Electrolytic Electrochemical Cell Water Bath Single Layer Double Layer

Discover our high-quality Multifunctional Electrolytic Cell Water Baths. Choose from single or double-layer options with superior corrosion resistance. Available in 30ml to 1000ml sizes.

Shaking Incubators for Diverse Laboratory Applications

Shaking Incubators for Diverse Laboratory Applications

Precision lab shaking incubators for cell culture & research. Quiet, reliable, customizable. Get expert advice today!

Button Battery Disassembly and Sealing Mold for Lab Use

Button Battery Disassembly and Sealing Mold for Lab Use

The simple sealing and disassembly mold can be directly used on ordinary tablet presses, which can save costs, is convenient and fast, and can be used to encapsulate and disassemble button batteries. Other specifications can be customized.

Battery Lab Equipment Battery Capacity and Comprehensive Tester

Battery Lab Equipment Battery Capacity and Comprehensive Tester

The scope of application of the battery comprehensive tester can be tested: 18650 and other cylindrical, square lithium batteries, polymer batteries, nickel-cadmium batteries, nickel-metal hydride batteries, lead-acid batteries, etc.


Leave Your Message