Knowledge How to determine mesh size of sieve? Master Particle Separation for Your Lab
Author avatar

Tech Team · Kintek Solution

Updated 6 days ago

How to determine mesh size of sieve? Master Particle Separation for Your Lab


Determining a sieve's mesh size is a straightforward process based on a simple physical count. You count the number of openings found within one linear inch of the screen. This number directly corresponds to the sieve's mesh designation; for example, a 100-mesh screen has 100 openings per linear inch.

While the mesh number is a simple count of openings, the critical insight is its inverse relationship to particle size. A higher mesh number always signifies smaller openings and the ability to separate finer particles.

The Principle of Sieve Mesh Sizing

The "Openings Per Inch" Standard

The U.S. mesh size standard is defined by the number of openings in the screening surface per linear inch. This measurement is counted from the center of one wire to a point one inch distant.

For example, a 4-mesh screen means there are four openings across one inch. A 325-mesh screen has 325 openings in that same span.

Visualizing the Inverse Relationship

Think of the mesh number like the resolution of a digital image (pixels per inch). A higher resolution means more, smaller pixels packed into the same space.

Similarly, a higher mesh number means more, smaller holes are packed into one inch of the sieve. This is the most important concept: as mesh number goes up, the size of the particle that can pass through goes down.

From Coarse to Fine

This system creates an intuitive scale. Low mesh numbers (e.g., 4, 8, 10) are used for coarse materials like gravel or coffee grounds. High mesh numbers (e.g., 100, 200, 400) are used for fine powders like flour or mineral dust.

Why Mesh Number Isn't the Whole Story

The Impact of Wire Diameter

The mesh number only tells you how many openings there are, not the exact size of those openings. The thickness of the wire used to weave the mesh also takes up space.

Two 100-mesh sieves can have different opening sizes if one is woven with a thicker wire than the other. The thicker wire will result in smaller openings.

The Role of Sieve Standards

To ensure consistency in science and industry, organizations like ASTM International and ISO define standard sieve series. The most common in the United States is ASTM E11.

These standards specify not only the mesh designation but also the nominal wire diameter, the permissible variations, and the resulting nominal opening size (in millimeters or micrometers). This guarantees that a No. 100 sieve from one certified manufacturer is functionally identical to a No. 100 sieve from another.

Understanding the Limitations

Effective Aperture vs. Nominal Size

Over time, sieve wires can stretch or sag from use, and abrasive materials can wear them down. This distortion changes the actual size and shape of the openings, affecting separation accuracy. Regular inspection and calibration are essential for precise work.

The Particle Shape Problem

Sieving assumes particles are roughly spherical. However, elongated or flat particles can pass through a mesh "end-on" or "sideways" even if their largest dimension is bigger than the mesh opening.

This means a sieve analysis technically separates particles based on their second-largest dimension.

The Sub-Sieve Range

For extremely fine particles (typically smaller than 38 micrometers, or a 400-mesh sieve), physical sieving becomes impractical. The fine wires are fragile, and particles tend to clump together due to electrostatic forces.

At this point, other methods like laser diffraction or air classification are used to determine particle size distribution.

Making the Right Choice for Your Goal

When selecting a sieve, your application determines the level of precision you need.

  • If your primary focus is general sorting (e.g., gardening, kitchen use): The basic mesh number is a perfectly adequate guide for separating coarse from fine materials.
  • If your primary focus is quality control or process manufacturing: You must use sieves certified to a specific standard (like ASTM E11) and reference the exact opening size in micrometers (µm) or millimeters (mm).
  • If your primary focus is scientific research or compliance: Rely exclusively on standardized sieve series and ensure your equipment is regularly calibrated to maintain accuracy and traceability.

Understanding how mesh size relates to both wire diameter and standardized openings empowers you to control particle separation with confidence.

How to determine mesh size of sieve? Master Particle Separation for Your Lab

Summary Table:

Key Aspect Description
Definition Number of openings in one linear inch of the sieve screen.
Core Principle Higher mesh number = smaller openings = finer particle separation.
Critical Factor Wire diameter affects the actual opening size; standards ensure consistency.
Common Standard ASTM E11 defines mesh numbers, wire diameters, and opening sizes.

Achieve precise and reliable particle sizing in your laboratory.
The correct sieve is fundamental to quality control, research, and process efficiency. KINTEK specializes in high-quality, certified lab sieves and equipment that meet ASTM and ISO standards, ensuring your results are accurate and reproducible.

Let our experts help you select the perfect sieve for your specific material and application.
Contact KINTEL today for a consultation and enhance your particle analysis workflow!

Visual Guide

How to determine mesh size of sieve? Master Particle Separation for Your Lab Visual Guide

Related Products

People Also Ask

Related Products

Laboratory Test Sieves and Vibratory Sieve Shaker Machine

Laboratory Test Sieves and Vibratory Sieve Shaker Machine

Efficiently process powders, granules, and small blocks with a high-frequency vibration sieve. Control vibration frequency, screen continuously or intermittently, and achieve accurate particle size determination, separation, and classification.

Three-dimensional electromagnetic sieving instrument

Three-dimensional electromagnetic sieving instrument

KT-VT150 is a desktop sample processing instrument for both sieving and grinding. Grinding and sieving can be used both dry and wet. The vibration amplitude is 5mm and the vibration frequency is 3000-3600 times/min.

Laboratory Vibratory Sieve Shaker Machine Slap Vibrating Sieve

Laboratory Vibratory Sieve Shaker Machine Slap Vibrating Sieve

KT-T200TAP is a slapping and oscillating sieving instrument for laboratory desktop use, with 300 rpm horizontal circular motion and 300 vertical slapping motions to simulate manual sieving to help sample particles pass through better.

Laboratory Wet Three-Dimensional Vibratory Sieve Shaker Machine

Laboratory Wet Three-Dimensional Vibratory Sieve Shaker Machine

The wet three-dimensional vibrating sieving instrument focuses on solving the sieving tasks of dry and wet samples in the laboratory. It is suitable for sieving 20g - 3kg dry, wet or liquid samples.

Custom PTFE Teflon Parts Manufacturer for PTFE Mesh F4 Sieve

Custom PTFE Teflon Parts Manufacturer for PTFE Mesh F4 Sieve

PTFE mesh sieve is a specialized test sieve designed for particle analysis in various industries, featuring a non-metallic mesh woven from PTFE filament. This synthetic mesh is ideal for applications where metal contamination is a concern . PTFE sieves are crucial for maintaining the integrity of samples in sensitive environments, ensuring accurate and reliable results in particle size distribution analysis.

Laboratory Vortex Mixer Orbital Shaker Multifunctional Rotation Oscillation Mixer

Laboratory Vortex Mixer Orbital Shaker Multifunctional Rotation Oscillation Mixer

The inching mixer is small in size, mixes quickly and thoroughly, and the liquid is in a vortex shape, which can mix all the test solutions attached to the tube wall.

Small Lab Rubber Calendering Machine

Small Lab Rubber Calendering Machine

Small lab rubber calendering machine is used for producing thin, continuous sheets of plastic or rubber materials. It is commonly employed in laboratories, small-scale production facilities, and prototyping environments to create films, coatings, and laminates with precise thickness and surface finish.

Automatic Laboratory Heat Press Machine

Automatic Laboratory Heat Press Machine

Precision automatic heat press machines for labs—ideal for material testing, composites, and R&D. Customizable, safe, and efficient. Contact KINTEK today!

Lab Internal Rubber Mixer Rubber Kneader Machine for Mixing and Kneading

Lab Internal Rubber Mixer Rubber Kneader Machine for Mixing and Kneading

Lab internal rubber mixer is suitable for mixing, kneading and dispersing various chemical raw materials such as plastics, rubber, synthetic rubber, hot melt adhesive and various low-viscosity materials.

Double Plate Heating Press Mold for Lab

Double Plate Heating Press Mold for Lab

Discover precision in heating with our Double Plate Heating Mold, featuring high-quality steel and uniform temperature control for efficient lab processes. Ideal for various thermal applications.

Metallographic Specimen Mounting Machine for Laboratory Materials and Analysis

Metallographic Specimen Mounting Machine for Laboratory Materials and Analysis

Precision metallographic mounting machines for labs—automated, versatile, and efficient. Ideal for sample prep in research and quality control. Contact KINTEK today!

Single Punch Tablet Press Machine and Mass Production Rotary Tablet Punching Machine for TDP

Single Punch Tablet Press Machine and Mass Production Rotary Tablet Punching Machine for TDP

Rotary tablet punching machine is an automatic rotating and continuous tableting machine. It is mainly used for tablet manufacturing in the pharmaceutical industry, and is also suitable for industrial sectors such as food, chemicals, batteries, electronics, ceramics, etc. to compress granular raw materials into tablets.

Rubber Vulcanizer Vulcanizing Machine Plate Vulcanizing Press for Lab

Rubber Vulcanizer Vulcanizing Machine Plate Vulcanizing Press for Lab

The Plate vulcanizing press is a kind of equipment used in the production of rubber products, mainly used for the vulcanization of rubber products. Vulcanization is a key step in rubber processing.

Single Punch Electric Tablet Press Machine Laboratory Powder Tablet Punching TDP Tablet Press

Single Punch Electric Tablet Press Machine Laboratory Powder Tablet Punching TDP Tablet Press

The single-punch electric tablet press is a laboratory-scale tablet press suitable for corporate laboratories in pharmaceutical, chemical, food, metallurgical and other industries.

Desktop Fast Laboratory Autoclave Sterilizer 35L 50L 90L for Lab Use

Desktop Fast Laboratory Autoclave Sterilizer 35L 50L 90L for Lab Use

The desktop fast steam sterilizer is a compact and reliable device used for rapid sterilization of medical, pharmaceutical, and research items. It efficiently sterilizes surgical instruments, glassware, medicines, and resistant materials, making it suitable for various applications.

Heated Hydraulic Press Machine with Integrated Manual Heated Plates for Lab Use

Heated Hydraulic Press Machine with Integrated Manual Heated Plates for Lab Use

Efficiently process heat-pressing samples with our Integrated Manual Heated Lab Press. With a heating range up to 500°C, it's perfect for various industries.

Custom PTFE Teflon Parts Manufacturer for Culture Dish and Evaporation Dish

Custom PTFE Teflon Parts Manufacturer for Culture Dish and Evaporation Dish

The PTFE culture dish evaporating dish is a versatile laboratory tool known for its chemical resistance and high-temperature stability. PTFE, a fluoropolymer, offers exceptional non-stick properties and durability, making it ideal for various applications in research and industry, including filtration, pyrolysis, and membrane technology.

Customizable High Pressure Reactors for Advanced Scientific and Industrial Applications

Customizable High Pressure Reactors for Advanced Scientific and Industrial Applications

This laboratory-scale high-pressure reactor is a high-performance autoclave engineered for precision and safety in demanding research and development environments.

Custom PTFE Teflon Parts Manufacturer for PTFE Measuring Cylinder 10/50/100ml

Custom PTFE Teflon Parts Manufacturer for PTFE Measuring Cylinder 10/50/100ml

PTFE measuring cylinder are a rugged alternative to traditional glass cylinders. They are chemically inert over a wide temperature range (up to 260º C), have excellent corrosion resistance and maintain a low coefficient of friction, ensuring ease of use and cleaning.

Small Jaw Crusher for Laboratory and Small Mines Efficient Flexible Affordable Laboratory Ore Crusher Coal Crusher

Small Jaw Crusher for Laboratory and Small Mines Efficient Flexible Affordable Laboratory Ore Crusher Coal Crusher

Discover the small jaw crusher for efficient, flexible, and affordable crushing in labs and small mines. Ideal for coal, ores, and rocks. Learn more now!


Leave Your Message